PT. PANCURAN ARTA ABADI

021-22687001 | ptpancuranartaabadi@gmail.com | 0812 9030 9065 

Lutron DO-5519

Lutron DO-5519

Lutron DO-5519 is a portable digital instrument designed to measure dissolved oxygen and temperature in water.

Features :

  • This Digital Oxygen meter is supplied with a polarographic type probe with an incorporated temp. sensor which serves for precise dissolved oxygen and temp measurement.
  • Applications for aquarium, medical research, agriculture, fish hatcheries, laboratory, water conditioning, mining industry, schools & colleges.
  • Heavy duty dissolved oxygen probe, probe head size can connect with BOD bottle
  • Separate probe with 4 meters cable.
  • Automatic temp. compensation from 0 to 50C for sensor.
  • Build in advanced setting procedures, it can adjust the % salt, height compensation value.
  • Microprocessor circuit assures high accuracy and provides special function and features.
  • Multi-display, show dissolved oxygen temp at the same time.
  • RS 232 PC serial interface.
  • Build in temperature C , F measurement.
  • LCD with two display, easy readout.
  • Manual and auto data logger, with flexible sampling time selection, can save max 1,600 reading data.
  • Temperature unit can default to C or F .
  • Microcomputer circuit, intelligent function, high accuracy.
  • Records maximum and minimum readings with recall.
  • Data hold function for freezing the desired value.
  • Build in the input socket for DC 9V power adapter.
  • RS232 PC serial interface.
  • Use the durable, long lasting components, including a heavy duty & compact ABS-plastic housing case.
Lutron DO-5519

Specifications :

  • Circuit : Custom one chip of microprocessor LSI circuit.
  • Measurement & range :
    • Dissolved Oxygen : 0 to 20,0 mg/L.
    • Oxygen in air : 0 to 100.0 %
    • Temperature : 0 to 50 C
  • Resolution :
    • Dissolved Oxygen : 0.1 mg/L
    • Oxygen in air : 0.1 % O2.
    • Temperature : 0.1 C
  • Accuracy :
    • Dissolved Oxygen : -+ 0.4 mg /L
    • Oxygen in air : -+ 0.7% O2
    • Temperature : -+ 0.8 C / 1.5 F
  • Sensor Structure : The polarographic type oxygen probe with an incorporated temperature sensor.
  • Probe Compensation and Adjustment :
    • Temperature : 0 to 50C
    • Salt : 0 to 39%
    • Height : 0 to 3,900 meter
  • Memory recall : Records maximum and minimum readings with recall.
  • Power off : auto power off saves battery life or manual off bu push button.
  • Data output : RS 232 PC serial interface.
  • Sampling time of data logger :
    • Manual : Push the data logger button once will save data one time.
    • Auto : 1, 2, 5, 10, 30, 60, 600, 1800, 3600 seconds.
  • Data logger number : Max 1,600 point data logger.
  • Data Hold : Freeze the display reading.
  • Sampling Time of display : Approx 1 second
  • Data Output : RS 232 PC serial interface.
  • Operating Temperature : 0 to 50 C
  • Operating Humidity : Less than 80% RH.
  • Power Supply : 006P DC 9V battery or DC 9V adapter input.
  • Power Current : Approx DC 6.2 mA
  • Weight : 446 g / 0.98 LB

Leave a Comment