Centrifugal Pump Calpeda NMM
Close coupled centrifugal pumps with screwed connection
Construction
- Close-coupled, centrifugal pumps; electric motor with extended shaft directly connected to the pump.
- NM, NM4: single-impeller
- NMD: with two back-to-back impellers (with axial thrust balancing).
- Rated speed of rotation (50 Hz):
- NM, NMD= 2900 rpm
- NM= 1450 rpm.
- Connections: threaded ports ISO 228/1 (BS 2779).
- NM, NMD: version with pump casing and lantern bracket in cast iron.
- BNM, BNMD: version with pump casing and lantern bracket in bronze.
- The pumps are supplied fully painted.

Applications Centrifugal Pump Calpeda NMM
- For clean liquids without abrasive, which are non-aggressive for the pump materials (solids content up to 0.2%).
- For water supply .
- For heating, air-conditioning, cooling and circulation plants.
- For civil and industrial applications.
- For irrigation.
Operating conditions
- Liquids temperature from-10deg.c. to +90deg.c.
- Ambient temperature up to 40deg.c.
- Total suction lift up to 7 m.
- Maximum permissible working pressure up to 10 bar (16 bar for pumps NMD 25/190; NMD 32/210; NMD 40/180).
- Continuous duty (S3 60% for single-phase pump to 1,5-1,8 kW).
Motor
- 2-pole induction motor,50 Hz (n= 2900 rpm).
- NM, NMD: single-phase
- 230/400 V +-10% up to 3kW;
- 400/690 V +- 10% from 4 to 9, 2 kW;
- NMM, NMDM: single-phase 230 V +- 10%, with thermal protector.
- 4-pole induction motor, 50 Hz (n= 1450 rpm).
- NM4: three-phase 230/400 V+- 10%.
- Insulation class F.
- Protection IP54.
- Motor suitable for suitable for operation with frequency converter from 0,37 kW for NM4 and from 1,1 kW for NM, NMD.
- IE2 efficiency class for single-phase motors up to 1,1 kW.
- EI3 efficiency class for three-phase motors (IE2 up to 0,65 kW).
- Constructed in accordance with:
- EN 60034-1, EN 60034-30-1,
- EN 60335-1, EN 60335-2-41.
Special features on request
- Other voltages.
- Frequency 60 Hz ( as per 60 Hz data sheet).
- IP protection: IP55
- Special mechanical seal
- Higher or lower liquid or ambient temperatures.
- Motor suitable for operation with frequency converter up to 0,33 kW for NM4 and up to 0,75 kW for NM,NMD.
Designation
- Example: BNMD(4)M 20/140A/B
- B= Bronze version (no indication: the pump is in the Cast Iron version)
- NM= Series
- D= Double impeller
- 4= 4-pole version (without indication, 2-pole version)
- M= Single-phase version (no indication: three-phase)
- 20= Delivery port diameter in mm
- 140= Nominal impeller diameter
- A= Impeller
- /B= It refers to a revision