PT. PANCURAN ARTA ABADI

021-22687001 | ptpancuranartaabadi@gmail.com | 0812 9030 9065 

Environment Meter EM-9000 Lutron

Environment Meter EM-9000 Lutron

Environment Meter EM-9000 Lutron is a multi function, 4 in 1 handheld dgital instrument designed to measure humidity, light, air velocity and temperature.

Features :

  • Environment instrument, mumlti function, all in one.
  • Type K / J thermometer, humidity / temp. meter, anemometer, light meter, sound level meter.
  • Thermocouple thermometer can default to accept type K / J temp. probe.
  • Temperature measurement can default the display unit to C to F.
  • Anemometer can default the display unit to m/S, FPM, Km/h, mph, knot.
  • Light meter can default the display unit to LUX or Ft-cd.
  • Meter can default auto power off or manual power off.
  • 0.1 degree resolution for temperature measurement.
  • Microcomputer circuit provides intelligent function and high accuracy.
  • LCD with two display, easy, readout.
  • Manual and auto data logger, with flexible sampling time selection, can save max 1.600 reading data.
  • Records maximum and minimum readings with recall.
  • Data hold function for freezing the desired value.
  • Build in the input socket for DC 9V power adapter.
  • RS232 PC serial interface.
  • Few panel buttons, easy operation.
  • Built in low battery indicator.
  • Heavy duty & compact housing case.
  • Available for the HVAC applications.
Environment Meter EM-9000 Lutron

General Specifications :

  • Circuit : Custom one chip of microprocessor LSI circuit.
  • Measurement : Type K / J thermometer. Humidity / Temp meter. Anemometer with temp. Light meter. Sound level meter.
  • Sampling time of data logger :
    • Manual : push the data logger button once will save data one time.
    • Auto : 1,2,5,10,30,60,600,1800,3600 seconds.
  • Data logger number : Max. 1,600 point data logger.
  • Temperature compensation : Automatic cold junction compensation both type K / J thermometer.
  • Linear Compensation : Linear compensation for the full range.
  • Input Socket : Standard 2 pin thermocouple socket.
  • Data Hold : freeze the display reading.
  • Memory Recall : Maximum and minimum value.
  • Sampling time of display : Approx 1 second.
  • Power off : Auto shut off to save battery life or manual off by push button.
  • Data Output : RS 232 PC serial interface.
  • Operating Temperature : 2 to 50C.
  • Operating Humidity : Less than 80% R.H
  • Power Supply : 006P DC 9V battery, DC 9V adapter input.
  • Power Current : Type K / J thermometer Approx. DC 6 mA. Humidity, Anemometer, Light Meter : Approx. DC 10 mA.
  • Weight : 306 g / 0.67 LB
  • Dimension : Meter : 135 x 60 x 33 mm. Probe : 105 x 46 x 29 mm.

Leave a Comment

Your email address will not be published. Required fields are marked *