PT. PANCURAN ARTA ABADI

021-22687001 | ptpancuranartaabadi@gmail.com | 0812 9030 9065 

Lutron YK-2005AH Anemometer

Lutron YK-2005AH Anemometer

Lutron YK-2005AH Anemometer is a professional digital hot-wire anemometer featuring a telescopic probe designed for precise low air velocity measurement and airflow volume calculations.

Features :

  • Combination of hot wire and standard thermistor, deliver rapid and precise measurement even at low air velocity value.
  • Air velocity : m/s, ft/min, km/h, knots, mile/h.
  • Air flow : CMM { m3/min } and CFM { ft3/min }
  • Air temperature { C , F }
  • Type K / J thermocouple thermometer.
  • Real time data logger, build in clock.
  • Auto or manual data record 16.000 data logger no.
  • Wide sampling time adjustment range from two seconds to 8 hours 59 minutes 59 seconds.
  • Zero adjustment.
  • Can default auto power off or manual power off.
  • Can default the air velocity, air flow, temp unit.
  • Air flow measurement can set the area dimension.
  • Large LCD with multiple display.
  • Data hold, record max and min reading.
  • Microcomputer circuit provides special function & offer high accuracy.
  • Air temp used thermistor sensor, fast response time.
  • Power by UM3 { 1.5V } x 4 battery or DC 9V adapter.
  • RS232 computer interface.
  • Separate probe, easy for remote measurement.
Lutron YK-2005AH Anemometer

General Specifications :

  • Circuit : Custom one chip of microprocessor LSI circuit.
  • Measurement unit :
    • Air velocity : m/s, km/h, ft/min, knot, mile/h
    • Air flow : CMM, CFM
    • Air temperature : C , F
    • Type K / J thermometer : C , F
  • Sampling time of data logger : 2 sec to 8 hour 59 min 59 sec
  • Sensor structure :
    • Air velocity & Air flow : tiny glass bead thermistor.
    • Air temperature : thermistor.
    • Type K / J thermometer : thermocouple.
  • Temperature compensation : Automatic temp compensation for the type K / J thermometer.
  • Data Hold : freeze the display reading.
  • Memory recall : maximum & minimum value.
  • Sampling time of display : Approx 1 second.
  • Power off : auto shut off saves battery life or manual off by push button.
  • Data Output : RS 232 PC serial interface.
  • Operating temperature : 0 to 50C
  • Operating Humidity : Less than 80% RH
  • Power Supply : DC 1.5V battery { UM3 } x 4 PCs heavy duty type. DC 9V adapter input. @ AC/DC power adapter is optional.
  • Power Supply : DC 3V silver battery. type CR2032.
  • Power Current : Approx. DC 21.5 mA @Main instrument. Approx. DC 70 mA @Main instrument + hot wire probe
  • Weight : 515 g / 1.13 LB.

Leave a Comment

Your email address will not be published. Required fields are marked *