PT. PANCURAN ARTA ABADI

021-22687001 | ptpancuranartaabadi@gmail.com | 0812 9030 9065 

PRESSURE REDUCING VALVE BAYARD

PRESSURE REDUCING VALVE BAYARD Control valve enabling reduction and Stabilisation of the downstream pressure.

PRESSURE REDUCING VALVE BAYARD

DESCRIPTION :

  • For general information concerning the operation of a hydrobloc control valve, please consult our general manual ( series K ).
  • Extensive range including two different designs:
    • XG Design:
      • Large flow capacity
      • Low head loss
      • Watertight T zero flow rate
    • XGS Design
      • Particularly suitable for pressure reduction,
      • Better cavitation resistance,
      • Watertight at zero flow rate,

CONSTRUCTION :

  • Self-lubricated double guided mobile unit,
  • Ductile iron body and design,
  • Stainless steel seat for standard version until DN 400 XG design and DN 600 XGS design,
  • Powder epoxy coating,
  • Stainless steel bolting,
  • Stainless steel pilot circuit tube and fittings,
  • Pilot circuit strainer with screen in stainless steel,
  • Individually packed

EASYY OPERATION AND MAINTENANCE

  • Visual position indicator with manual drain
  • Including isolating valve ( s )for pressure gauges,
  • Equipped with opening speed controller “RO” 9 DN50 to 300 XG design, and DNI150 to 400 XGS design only )
  • Chamber isolating valve independent from the adjustment of the speed controller,
  • Maintenance without disassembly from the pipeline.
  • Easy dismantling from the top.
  • Drain plug ( stainless steel )
  • Product according to standard EN 1074-5

TECHNICAL DATA PRESSURE REDUCING VALVE BAYARD:

  • Range :
    • DN 50 t0 600 for XG design.
    • DN 150 to for XGS design.
    • DN 800 to 100 XG and XGS design, please consult us.
  • PN 25.
  • Maximum temperature: +10C to+650C
  • Seating : class A according to standards ISO 5208-2
  • Face-to-face dimensions according to standard EN 558-1 SERIES 1 ( Expect DN1000 ) And ISO5752
    series 1 ( Expect DN1000 )
  • Flange drilling according to standard EN 1092-2 and ISO 7005-2 : ISO PN 10, 16 or 25 for DN50 to
    1000 ( other drillings, please consult us ).
  • Fluid drinking water or 2 mm filtered untreated water.
  • Working pressure 25 Bar.
  • Vertical & Horizontal intallation.
  • The valve body of PN 16 and PN25 are the same, the diffference are on flange drlling and plot circuit.

FUNCTIONS :

  • Reduces and stabilises a higher inlet pressure to a steady lower downstream pressure regardless of variations of flow and/or inlet pressure.
  • Close/ open and puts into regulation with hand

APPLICATIONS :

  • To regulate multi pressure level network.
  • To supply water to a flow pressure level network from a high pressure level network.
  • To protect a device, private consumers installations, or sections of the network against excessive pressure and high upstream pressure variations,
  • To reduce leakage thanks to the control of the supplying pressure,
  • To save water consumption by a reduction in pressure, etc.

Leave a Comment