PT. PANCURAN ARTA ABADI

021-22687001 | ptpancuranartaabadi@gmail.com | 0812 9030 9065 

YK-2005AM Anemometer Lutron

YK-2005AM Anemometer Lutron

YK-2005AM Anemometer Lutron is a digital metal vane anemometer with a built-in real time data logger, air flow measurement and temperature/thermocouple capabilities.

Features :

  • Air Velocity : m/s, ft/min, km/h, knots, mile/h.
  • Air Flow : CMM {m^3/min } and CFM { ft^3/min }.
  • Air temperature { ℃ ℉ }
  • Type K/J thermocouple thermometer.
  • Real time data logger, build in clock { hour, min, sec, year, month, date }.
  • Auto or manual data record, 16.000 data logger no.
  • Wide sampling time adjustment range from two second to 8 hours 59 minutes 59 second.
  • RS232 computer interface.
  • Can default auto power off or manual power off.
  • Can default the air velocity, air flow, temp unit.
  • Air flow measurement can set the area dimension.
  • Multi function with easy operation.
  • Low friction ball vane wheels make sure high & low velocities.
  • Metal vane, high reliability.
  • Large LCD with multiple display.
  • Data hold, record max and min reading.
  • Microcomputer circuit provides special function & offer high accuracy.
  • Air temp. used thermistor sensor, fast response time.
  • Power by UM3 { 1.5V } x 4 batteries or DC 9V adapter.
  • RS232 PC serial interface.
  • Separate probe, easy for operation of different measurement environment.
YK-2005AM Anemometer Lutron

General Specifications :

  • Circuit : custom one chip of microprocessor LSI circuit.
  • Display : LCD size : 58 x 34 mm.
  • Measurement Unit :
    • Air velocity : m/s, km/h, ft/min, knots, mile/h.
    • Air flow : CMM { m^3/min., cube meter per min }, CFM { m^3/min., cube feet per min }
    • Air temperature : ℃ ℉
    • Type K/J thermometer.
  • Sampling Time of data logger :
    • Manual : push the data logger button once will save data one time.
    • Auto : 2 sec to 8 hour 59 min. 59 sec.
  • Sensor Structure :
    • Air velocity & air flow : Conventional twisted van arm and low friction ball bearing design, vane use metal material.
    • Air temperature : thermistor.
    • Type K/J thermometer : Thermocouple.
  • Temperature compensation : Automatic temp. compensation for the Type K/J thermometer.
  • Data Hold : Freeze the display reading.
  • Memory Recall : Maximum & Minimum value.
  • Sampling Time of display : Approx 1 second.
  • Power off : Auto shut off saves battery life or manual off by push button.
  • Data output : RS 232 PC serial interface.
  • Operating Temperature : 0 to 50℃
  • Operating Humidity : Less than 80% R.H.
  • Power Supply :
    • DC 1,5 V battery ( UM3 ) x 4 PCs, ( Heavy duty type )
    • DC 9V adapter input @ AC/DC power adapter is optional.
  • Power Supply : DC 3V silver battery. Type : CR2032.
  • Power Current : Approx. DC 21.5 mA. Main instrument. DC 27.5 mA. Main instrument. + Anemometer probe.
  • Weight : 515 g/ 1.13 LB. @Battery is included
  • Dimension :
    • Main instrument : 203 x 76 x 38 mm
    • Anemometer sensor head : Round, 72 mm Dia.

Leave a Comment